There might be the issue with library settings. User need to make sure that they are using same Library and Units setting in both MLM and MDTools. Any Cavity created in MLM with mm settings will be available in MDTools with mm settings only. Changing
Go to Cavities. Select the new manufacturer library you want to import the cavity into. Click Add. Click Import Cavity Data and select a cavity. Delete the cavity from the original manufacturer library folder if desired.
If you get an 'Unspecified error' while stating a new part file or inserting a cavity in a newly created block, apply the following. If MDTools cannot find the library, ensure the following: Ensure you have full permissions to 'Users' for folder ...
Virtual Cavity mode: Virtual cavity mode was created to enhance performance as all CAD applications tends to slow down exponentially with the number of features. In Virtual Cavity mode no feature is created, temporary Graphics are used to display ...
Feature failure issue is due to zero-thickness geometry limitation of SolidWorks and is resolved by deselecting the highlighted setting from the SolidWorks settings. Go to System Options > Performance, then deselect the highlighted option as shown ...